Ranch and Coast Electric
Commercial

Commercial Generator Sizing Guide: How to Choose the Right Backup Power

By Ranch and Coast Electric|Updated 2025-01-27|14 min read
# Commercial Generator Sizing Guide: How to Choose the Right Backup Power A power outage that lasts four hours can cost a mid-sized restaurant $10,000 in spoiled food alone. A medical office without electricity faces regulatory violations within minutes. A warehouse with refrigerated inventory can lose an entire shipment in a single afternoon. For Florida businesses, backup power is not a luxury or a nice-to-have feature. It is infrastructure that protects revenue, safety, and reputation. This guide provides a step-by-step methodology for sizing a commercial generator correctly. We cover the electrical calculations, fuel type comparisons, transfer switch configurations, Florida-specific hurricane requirements, maintenance schedules, and realistic cost ranges. Whether you operate a single storefront or a multi-building campus, the principles here will help you make a sound investment. ## Table of Contents - [Why Backup Power Matters for Florida Businesses](#why-backup-power-matters-for-florida-businesses) - [Understanding Power Requirements: kW vs kVA](#understanding-power-requirements-kw-vs-kva) - [Step-by-Step Commercial Generator Sizing](#step-by-step-commercial-generator-sizing) - [Generator Sizing by Business Type](#generator-sizing-by-business-type) - [Single-Phase vs Three-Phase Generators](#single-phase-vs-three-phase-generators) - [Fuel Type Comparison](#fuel-type-comparison) - [Automatic Transfer Switch Options](#automatic-transfer-switch-options) - [Florida Hurricane Preparedness and Building Codes](#florida-hurricane-preparedness-and-building-codes) - [Generator Maintenance Requirements](#generator-maintenance-requirements) - [Commercial Generator Cost Ranges](#commercial-generator-cost-ranges) - [Common Sizing Mistakes to Avoid](#common-sizing-mistakes-to-avoid) - [When to Call a Professional](#when-to-call-a-professional) ## Why Backup Power Matters for Florida Businesses Florida ranks second in the nation for power outages. The state experiences an average of 15 significant outage events per year, driven by a combination of hurricane season (June through November), severe thunderstorms, lightning strikes (Florida is the lightning capital of the United States), and an aging grid infrastructure that struggles under peak summer demand. ### The Real Cost of Downtime The cost of a power outage extends far beyond the obvious loss of lighting. Consider the following real-world impacts by business type: **Revenue loss**: A retail store averaging $2,000/hour in sales loses that revenue for every hour without power. A restaurant operating during dinner service can lose $3,000-$5,000 in a single evening. These numbers compound quickly during multi-day outage events, which are common after hurricanes. **Inventory spoilage**: Businesses that store perishable goods, pharmaceutical products, or temperature-sensitive materials face immediate inventory loss. FDA regulations require that refrigerated food held above 40 degrees Fahrenheit for more than four hours must be discarded. A single commercial walk-in cooler can hold $15,000-$50,000 in product. **Data and equipment damage**: Power outages cause hard shutdowns of servers, POS systems, and industrial equipment. Sudden shutdowns can corrupt databases, damage hard drives, and require expensive recovery procedures. The average cost of data recovery after a hard crash runs $1,000-$7,500. **Liability and compliance**: Medical offices, pharmacies, and food service businesses face regulatory consequences when power loss compromises patient safety or food safety. Assisted living facilities in Florida are required by law to have generator backup following the 2017 Rehabilitation Center at Hollywood Hills tragedy, where 12 residents died after Hurricane Irma knocked out air conditioning. **Employee costs**: Your staff is on the clock whether the power is on or not. Sending employees home means paying for unproductive hours and disrupting schedules. For a business with 20 employees at an average rate of $20/hour, every lost hour costs $400 in wages alone. ### Grid Reliability Trends Florida's grid is under increasing strain. Population growth continues to push demand higher, while the transition to renewable energy introduces intermittency challenges. The 2024-2025 hurricane seasons demonstrated that even well-prepared utilities need days or weeks to restore power after major storms. Businesses with backup generators remained operational while competitors stayed dark. ## Understanding Power Requirements: kW vs kVA Before sizing a generator, you need to understand the units of measurement. Commercial generators are rated in both kilowatts (kW) and kilovolt-amperes (kVA), and these are not the same number. ### kW (Kilowatts) - Real Power Kilowatts measure the actual usable power that does work: running motors, producing light, heating elements. This is the number that matters for sizing your loads. ### kVA (Kilovolt-Amperes) - Apparent Power kVA measures the total power flowing through the electrical system, including the power that is "wasted" in maintaining magnetic fields in motors and transformers. kVA is always equal to or greater than kW. ### Power Factor The relationship between kW and kVA is called the power factor (PF): **kW = kVA x Power Factor** Most commercial facilities operate at a power factor between 0.80 and 0.85. This means a generator rated at 100 kVA with a 0.8 power factor delivers only 80 kW of usable power. Why does this matter? If your facility needs 80 kW of real power and you purchase a 80 kVA generator thinking it is the same thing, you will be 16 kW short. Always confirm whether a generator's rating is in kW or kVA, and always size based on kW requirements. **Quick conversion table:** | Generator kVA Rating | Power Factor 0.80 | Power Factor 0.85 | |----------------------|--------------------|--------------------| | 50 kVA | 40 kW | 42.5 kW | | 100 kVA | 80 kW | 85 kW | | 150 kVA | 120 kW | 127.5 kW | | 200 kVA | 160 kW | 170 kW | | 500 kVA | 400 kW | 425 kW | ## Step-by-Step Commercial Generator Sizing Proper generator sizing follows a structured process. Skipping steps leads to undersized or oversized equipment, both of which cost you money. ### Step 1: Conduct a Load Inventory Walk through your facility and list every piece of electrical equipment. For each item, record three values: - **Nameplate wattage or amperage** (found on the equipment label) - **Running load** (the continuous power draw during normal operation) - **Starting load** (the momentary surge when motors or compressors start, typically 2-6 times the running load) For equipment rated in amps rather than watts, convert using this formula: **Single-phase: Watts = Volts x Amps x Power Factor** **Three-phase: Watts = Volts x Amps x Power Factor x 1.732** ### Step 2: Categorize Loads by Priority Not all loads are equally critical. Divide your equipment into three tiers: **Critical loads** (must remain powered at all times): Life safety systems, fire alarms, emergency lighting, refrigeration for perishable goods, security systems, IT servers, and any equipment where shutdown causes damage or safety hazards. **Essential loads** (should remain powered for business continuity): HVAC systems, POS systems, primary lighting, communication systems, production equipment. **Deferrable loads** (can be temporarily shed): Non-essential lighting, decorative systems, break room appliances, non-critical outlets. ### Step 3: Calculate Total Connected Load Add up all running loads for the equipment you intend to power. Then identify the single largest starting load in the system, because the generator must handle that motor's startup surge on top of everything else already running. ### Step 4: Apply the Safety Factor The industry-standard safety factor for commercial generator sizing is 25 percent. This accounts for load growth, unexpected peak demands, and ensures the generator runs at a healthy load level rather than at maximum capacity. **Total Generator Size (kW) = (Sum of All Running Loads + Largest Starting Load Surge) x 1.25** For example, if your running loads total 60 kW and your largest motor has a starting surge of 15 kW above its running load: Total = (60 + 15) x 1.25 = 93.75 kW You would select a 100 kW generator. ### Step 5: Account for Future Growth If you plan to expand operations, add equipment, or lease additional space within the next 5-10 years, factor that growth into your sizing now. Adding generator capacity later requires either replacing the unit entirely or installing a second paralleled generator, both of which are significantly more expensive than sizing correctly from the start. ## Generator Sizing by Business Type The following table provides typical generator sizing ranges based on real-world commercial load profiles. These ranges assume standard equipment, Florida-appropriate HVAC loads, and backup of all critical and essential systems. | Business Type | Square Footage | Typical Load Range | Recommended Generator | Key Loads | |---------------|---------------|--------------------|-----------------------|-----------| | Restaurant | 3,000 sq ft | 36-60 kW | 45-75 kW | Walk-in coolers, hoods, HVAC, cooking equipment, POS | | Office Building | 10,000 sq ft | 48-80 kW | 60-100 kW | HVAC, lighting, computers, servers, elevators | | Warehouse | 50,000 sq ft | 80-200 kW | 100-250 kW | Lighting, dock doors, forklifts, refrigeration | | Medical Office | 5,000 sq ft | 40-64 kW | 50-80 kW | Medical equipment, HVAC, lighting, vaccine storage | | Retail Store | 5,000 sq ft | 24-40 kW | 30-50 kW | Lighting, HVAC, POS, security, signage | | Grocery Store | 15,000 sq ft | 100-160 kW | 125-200 kW | Refrigeration cases, HVAC, lighting, POS | | Auto Dealership | 20,000 sq ft | 80-120 kW | 100-150 kW | Service lifts, compressors, lighting, HVAC | | Data Center | 5,000 sq ft | 200-800 kW | 250-1,000 kW | Server racks, cooling, UPS systems | ### Why Restaurants Need More Power per Square Foot Restaurants have the highest power density of any standard commercial space. A 3,000-square-foot restaurant typically requires 45-75 kW because it operates multiple high-draw systems simultaneously: commercial refrigeration (walk-in coolers and freezers drawing 3-8 kW each), kitchen ventilation hoods (2-5 kW), commercial HVAC sized for kitchen heat loads, gas or electric cooking equipment, and point-of-sale systems. The startup surge from multiple compressors is the primary sizing driver. ### Why Medical Offices Have Strict Requirements Medical offices must maintain power for vaccine refrigerators (which must stay between 35-46 degrees Fahrenheit), medical imaging equipment, sterilization autoclaves, and electronic health record systems. The Florida Board of Medicine expects medical practices to have contingency plans for power loss, and many malpractice insurers offer premium discounts for facilities with standby generators. ## Single-Phase vs Three-Phase Generators The choice between single-phase and three-phase power depends on the equipment in your facility. **Single-phase generators** (120/240V) are appropriate for small commercial operations that run standard equipment: lighting, small HVAC units, computers, refrigeration, and outlets. Most businesses under 50 kW with no large motors or industrial equipment can operate on single-phase power. **Three-phase generators** (120/208V or 277/480V) are required when your facility has three-phase motors (common in large HVAC systems, compressors, elevators, and industrial machinery), when your utility service is three-phase, or when your total load exceeds approximately 50 kW. Three-phase power is more efficient for large motors and allows smaller wire sizes for the same amount of power delivery. A critical rule: **your generator must match your facility's electrical distribution**. If your building is wired for three-phase power, you need a three-phase generator. Installing a single-phase generator on a three-phase system will not power your three-phase equipment and can create dangerous voltage imbalances. If you are unsure whether your facility uses single-phase or three-phase power, check your utility meter or main electrical panel. Three-phase panels have three main breaker poles; single-phase panels have two. A [commercial electrical services](/commercial/generators) professional can verify this during a site evaluation. ## Fuel Type Comparison Commercial generators run on four primary fuel types. Each has distinct advantages depending on your location, runtime requirements, and infrastructure. | Feature | Natural Gas | Diesel | Propane (LP) | Bi-Fuel (Diesel + Natural Gas) | |---------|------------|--------|--------------|-------------------------------| | **Fuel Availability** | Unlimited (pipeline) | Requires tank + delivery | Requires tank + delivery | Pipeline + tank | | **Runtime** | Unlimited | Limited by tank size | Limited by tank size | Extended beyond diesel alone | | **Fuel Cost per kWh** | $0.06-$0.10 | $0.08-$0.14 | $0.10-$0.16 | $0.07-$0.11 | | **Fuel Shelf Life** | N/A | 12-18 months | Indefinite | Diesel: 12-18 months | | **Starting Reliability** | Excellent | Excellent (best in cold) | Excellent | Excellent | | **Emissions** | Lowest | Highest | Low | Moderate | | **Generator Cost** | Moderate | Higher | Moderate | Highest | | **Maintenance Cost** | Lower | Higher (fuel filtering) | Lower | Moderate | | **Best For** | Urban businesses on gas lines | Large facilities, long runtimes | Rural locations without gas | Facilities needing extended runtime | | **Size Range Available** | Up to 400 kW | Up to 3,000+ kW | Up to 200 kW | Up to 2,000 kW | ### Natural Gas Advantages in Florida Most urban and suburban commercial properties in the Tampa Bay, Sarasota, and Bradenton areas have access to natural gas service. Natural gas generators connect directly to the gas line, which means you never run out of fuel. This is a significant advantage during prolonged hurricane outages when diesel delivery trucks cannot reach your location. Gas line pressure can drop during extreme demand events, but this is uncommon in commercial service areas. ### Diesel for Large Facilities Diesel generators dominate above 200 kW because diesel engines produce more power per unit of fuel and are available in much larger sizes. Diesel fuel requires on-site storage tanks, typically 250-1,000 gallons for commercial applications. Florida fire codes and EPA regulations govern tank placement, containment, and leak detection. A 500-gallon tank running a 150 kW generator at 75 percent load provides approximately 48-60 hours of runtime. ### Bi-Fuel: The Best of Both Worlds Bi-fuel generators start on diesel for reliable ignition, then blend in natural gas during operation. This stretches diesel fuel supply by 50-70 percent while maintaining the reliability of diesel starting. Bi-fuel is an excellent choice for facilities that need both the unlimited runtime of natural gas and the starting reliability and high-power capability of diesel. ## Automatic Transfer Switch Options The automatic transfer switch (ATS) is the device that detects a power outage, signals the generator to start, and transfers your building's electrical load from utility power to generator power. Choosing the right ATS is just as important as choosing the right generator. ### Open Transition Transfer Switch An open transition ATS (also called break-before-make) briefly disconnects the load from utility power before connecting it to generator power. There is a momentary interruption of 50-100 milliseconds during the transfer. This is the most common and least expensive option, suitable for most commercial applications where a sub-second interruption is acceptable. **Cost: $2,000-$8,000 depending on amperage rating.** ### Closed Transition Transfer Switch A closed transition ATS (also called make-before-break) briefly parallels the generator with the utility during transfer, providing zero interruption. For a fraction of a second (typically under 100 milliseconds), both power sources are connected. This requires synchronization equipment and is more expensive, but eliminates any power interruption during transfer. **Cost: $5,000-$15,000 depending on amperage rating.** Closed transition is recommended for data centers, medical facilities, and any operation where even a 100-millisecond interruption causes problems (such as loss of process in manufacturing or dropped calls in call centers). ### Transfer Time Settings Most ATS units are configured with the following time delays: - **Utility failure detection**: 3-5 seconds (prevents transfer during momentary flickers) - **Generator start and stabilization**: 10-30 seconds (allows the engine to reach operating speed and voltage) - **Transfer to generator**: Total elapsed time from outage to generator power is typically 10-30 seconds - **Retransfer to utility**: 5-30 minutes after utility power is restored and stable (prevents transferring back during unstable restoration) For businesses that cannot tolerate any interruption, even the 10-30 seconds of generator startup, an uninterruptible power supply (UPS) system bridges the gap between utility failure and generator startup. UPS systems provide instant battery-backed power for those critical seconds. ## Florida Hurricane Preparedness and Building Codes Florida building codes impose specific requirements on commercial generator installations that go beyond standard electrical codes. ### Florida Building Code Requirements **Wind resistance**: Generator enclosures in Florida must be rated for the wind speeds specified in the Florida Building Code for your location. Most of the Tampa Bay and Sarasota region falls in the 150-170 mph wind speed zone. Generator enclosures must be anchored to concrete pads designed to resist uplift forces, and the enclosure itself must be rated for the applicable wind speed. **Flood zone compliance**: If your property is in a flood zone (common in coastal Florida), the generator must be elevated above the base flood elevation (BFE). FEMA requires critical equipment to be at least one foot above BFE. Some local jurisdictions, including Pinellas County, require two feet above BFE. **Fuel storage**: Florida Fire Prevention Code Chapter 57 governs above-ground fuel storage tanks. Tanks above 660 gallons require fire department approval, secondary containment, and may require fire suppression systems. Diesel tanks near waterways require additional environmental protections. **Setback requirements**: Generators must meet minimum setback distances from property lines, building openings, and air intakes. Typical requirements are 5 feet from any opening into a building and 3 feet from property lines, but local jurisdictions vary. **Sound ordinances**: Many Florida municipalities enforce noise limits of 65-75 dB at the property line. Larger generators may require sound-attenuated enclosures (adding $3,000-$10,000 to the project cost) to meet local ordinances. ### Hurricane-Specific Preparations Beyond code compliance, practical hurricane preparation for generators includes: - **Fuel management**: Fill diesel or propane tanks before hurricane season. During storm warnings, fuel delivery becomes unreliable or impossible. Natural gas generators avoid this issue entirely. - **Storm damage protection**: Install impact-resistant enclosures or position generators where they are shielded from windborne debris. Avoid placement near trees or structures that could fall on the unit. - **Post-storm inspection**: After any hurricane or tropical storm, inspect the generator and transfer switch before operating. Check for water intrusion, debris in the cooling system, and damage to fuel lines or electrical connections. - **Load shedding plan**: Develop a written plan for which loads to shed if fuel supply becomes limited during an extended outage. Prioritize life safety and inventory preservation. ## Generator Maintenance Requirements A commercial generator that sits unused and unmaintained will likely fail when you need it most. The National Fire Protection Association (NFPA 110) sets minimum maintenance and testing requirements for emergency and standby power systems. ### Weekly Testing Run the generator under load for a minimum of 30 minutes every week. Most modern commercial generators have automatic exerciser controls that start the unit on a programmed schedule. Weekly testing verifies that the engine starts reliably, the transfer switch operates correctly, and all systems are functioning. ### Monthly Inspections Perform a visual inspection monthly. Check engine oil level, coolant level, battery condition and electrolyte level, fuel level, and look for any fluid leaks, loose connections, or signs of rodent intrusion. In Florida, check for signs of corrosion, especially in coastal areas where salt air accelerates deterioration. ### Semi-Annual Service Every six months, a qualified technician should perform the following: - Change engine oil and oil filter - Replace fuel filters - Inspect and clean the air filter (replace annually) - Test battery charging system and battery load test - Inspect coolant hoses and belts - Test all safety shutdowns (low oil pressure, high temperature, overspeed, overcrank) - Verify transfer switch operation under load - Inspect and tighten all electrical connections ### Annual Comprehensive Service Once per year, typically before hurricane season begins in June, schedule a comprehensive service that includes everything above plus: - Full load bank test (run the generator at 100% rated load for 2 hours) - Coolant analysis and replacement if needed - Fuel quality testing (diesel only) - Exhaust system inspection - Governor and voltage regulator calibration - Complete transfer switch maintenance and testing A [preventive maintenance program](/commercial/generators) ensures your generator receives all required service on schedule and is ready when storms arrive. ## Commercial Generator Cost Ranges Commercial generator pricing varies based on size, fuel type, enclosure type, and installation complexity. The following ranges include the generator, transfer switch, concrete pad, and standard installation for Florida commercial applications. | Generator Size | Typical Application | Equipment + Installation Cost | Annual Maintenance Cost | |---------------|--------------------|-----------------------------|------------------------| | 20 kW | Small retail, offices | $8,000 - $15,000 | $500 - $800 | | 60 kW | Mid-size restaurant, medical office | $20,000 - $35,000 | $800 - $1,200 | | 100 kW | Large restaurant, small warehouse | $30,000 - $50,000 | $1,000 - $1,500 | | 150 kW | Large office building, medium warehouse | $40,000 - $80,000 | $1,200 - $2,000 | | 250 kW | Large warehouse, grocery store | $65,000 - $120,000 | $1,500 - $2,500 | | 500 kW | Large facility, campus | $100,000 - $200,000 | $2,500 - $4,000 | ### What Drives Cost Variation The wide cost ranges above reflect real variables in commercial generator projects: **Site conditions**: Rocky soil, difficult access, long conduit runs, or elevated installations (for flood zone compliance) add $2,000-$15,000 to installation costs. **Utility coordination**: Some installations require utility company upgrades or modifications to the service entrance, which can add $3,000-$20,000 and several weeks to the timeline. **Sound attenuation**: If your location requires a sound-attenuated enclosure to meet noise ordinances, add $3,000-$10,000 to the equipment cost. **Fuel infrastructure**: Natural gas generators may require gas line upsizing. Diesel generators require tank installation, containment, and fuel management systems. Propane systems need tank rental or purchase and initial fill. **Permitting and engineering**: Commercial generator installations in Florida require electrical permits, and larger systems require engineered drawings. Engineering fees range from $1,500-$5,000, and permit fees from $200-$1,000 depending on jurisdiction. ## Common Sizing Mistakes to Avoid Having installed hundreds of commercial generators across the Tampa Bay and Sarasota region, we see the same mistakes repeatedly: **Mistake 1: Sizing based on square footage alone.** Square footage is a starting point, not an answer. A 5,000-square-foot medical office with imaging equipment has completely different power requirements than a 5,000-square-foot retail store. Always perform a load calculation. **Mistake 2: Forgetting motor starting loads.** A 10-horsepower HVAC compressor runs at about 8 kW but requires 24-48 kW to start. If your generator cannot handle the starting surge, the compressor will not start, or it will stall the generator. Large motor starting loads are the single most common cause of generator undersizing. **Mistake 3: Ignoring future growth.** A generator installed today should serve your business for 20-30 years. If you plan to add equipment, expand square footage, or increase operations, size for that future state now. Adding a 25 percent growth allowance beyond the standard 25 percent safety factor is wise for growing businesses. **Mistake 4: Choosing the cheapest option.** A generator that fails during a hurricane costs your business far more than the savings from purchasing a lower-quality unit. Invest in commercial-grade equipment from established manufacturers (Generac, Kohler, Cummins, Caterpillar) with proven track records and available parts and service networks in Florida. **Mistake 5: Neglecting maintenance.** A $50,000 generator that has not been maintained is a $50,000 paperweight. Budget for annual maintenance costs (1.5-3 percent of equipment value per year) and commit to the weekly, monthly, and annual service schedule. **Mistake 6: Not considering paralleling.** For larger facilities or those with high reliability requirements, two smaller generators operating in parallel provide redundancy that a single large generator cannot. If one unit fails or requires maintenance, the other continues to carry critical loads. Paralleling adds 15-25 percent to total project cost but significantly increases reliability. ## When to Call a Professional Generator sizing for commercial applications is not a DIY project. The electrical calculations, code compliance requirements, fuel system design, and permitting process require expertise that takes years to develop. You should engage a professional electrical contractor when: - You are unsure of your facility's total electrical load or service type (single-phase vs three-phase) - Your facility has large motors, variable frequency drives, or sensitive electronic equipment - You are in a flood zone or high-velocity hurricane zone - Your project requires utility company coordination - You need to parallel multiple generators - You are replacing an existing generator and want to verify proper sizing - You need to integrate the generator with a building management system or fire alarm panel A qualified contractor will perform a comprehensive load analysis, recommend the right equipment for your specific application, handle all permitting and inspections, and coordinate with the utility company. The cost of professional design and installation is a fraction of the cost of getting it wrong. Contact [Ranch and Coast Electric](/commercial/generators) for a commercial generator sizing consultation. We serve businesses throughout Tampa, Sarasota, Bradenton, and the surrounding region with expert generator sales, installation, and ongoing maintenance programs. Our team will evaluate your facility, calculate your exact power requirements, recommend the right equipment, and provide a detailed proposal with transparent pricing. Backup power is an investment in your business's resilience. Size it right the first time, maintain it properly, and it will protect your operation for decades to come.

Need Help With Your Electrical Project?

Ranch and Coast Electric provides free estimates for all electrical services across Tampa Bay.

Call Now